Spif

UQ state-dependent framework for seismic fragility assessment of industrial components featured image

UQ state-dependent framework for seismic fragility assessment of industrial components

A state-dependent seismic fragility framework combining polynomial chaos expansions and bootstrapping is proposed and validated, enabling efficient fragility assessment of …

avatar
Chiara Nardin
•
State-dependent seismic fragility functions for bolted flange joints on special-risk industrial substructures featured image

State-dependent seismic fragility functions for bolted flange joints on special-risk industrial substructures

State-dependent seismic fragility functions for bolted flange joints, obtained from a calibrated FE model of the SPIF braced frame, seismic sequences from a site-based ground …

avatar
Chiara Nardin
•
State-dependent seismic fragility functions for vertical tanks installed on major hazard industrial substructure module featured image

State-dependent seismic fragility functions for vertical tanks installed on major hazard industrial substructure module

State-dependent seismic fragility functions for vertical tanks on an industrial braced-frame substructure, combining a calibrated FE model, seismic sequences and bootstrapped PCE …

avatar
Chiara Nardin
•
Modelling of non-structural components of an industrial multi-storey frame for seismic risk assessment featured image

Modelling of non-structural components of an industrial multi-storey frame for seismic risk assessment

Coupled modelling of an industrial multi-storey frame (MRF and braced configurations) and its non-structural components, with SCoRes-based record selection, to assess the seismic …

avatar
Gianluca Quinci
•
Seismic experimental analyses and surrogate models of multi-component systems in special-risk industrial facilities featured image

Seismic experimental analyses and surrogate models of multi-component systems in special-risk industrial facilities

Doctoral thesis (Doctor Europaeus, University of Trento): a computational framework for seismic state-dependent fragility analysis of industrial non-structural components, …

avatar
Chiara Nardin
•
Experimental performance of a multi-storey braced frame structure with non-structural industrial components subjected to synthetic ground motions featured image

Experimental performance of a multi-storey braced frame structure with non-structural industrial components subjected to synthetic ground motions

Shake table tests on a full-scale multi-storey braced frame steel structure with non-structural industrial components, excited with a synthetic site-based ground motion model to …

avatar
Chiara Nardin
•
Seismic performance of an industrial multi-storey frame structure with process equipment subjected to shake table testing featured image

Seismic performance of an industrial multi-storey frame structure with process equipment subjected to shake table testing

Shake table tests within the SPIF project on a full-scale industrial multi-storey moment resisting frame with process equipment: structure-equipment interaction and check of floor …

avatar
Christoph Butenweg
•
Shake table testing for a multi-component prototype industrial plant: input and system modelling issues featured image

Shake table testing for a multi-component prototype industrial plant: input and system modelling issues

Input and system modelling issues of the SPIF shake table campaign on a full-scale multi-component industrial steel frame, highlighting structure-equipment dynamic interaction.

avatar
Chiara Nardin
•
Experimental investigation on the seismic performance of a multi-component system for major-hazard industrial facilities featured image

Experimental investigation on the seismic performance of a multi-component system for major-hazard industrial facilities

Experimental setup, measurements and observed damage of the SPIF shake table tests on a three-storey steel frame with vessels, cabinets and piping, with findings on performance …

avatar
Christoph Butenweg
•
Bolted flange joints equipped with FBG sensors in industrial piping systems subjected to seismic loads featured image

Bolted flange joints equipped with FBG sensors in industrial piping systems subjected to seismic loads

This paper addresses the vulnerability of industrial plants to natural hazards (NaTech) by evaluating Optical Fiber Bragg Gratings (FBGs) for monitoring bolted flange joints (BFJ) …

avatar
Fabrizio Paolacci
•